📌 Adding The Implant Library In exocad
L Exporting PIM Data To exocad From DOFSync
L Importing PIM Data In exocad
📌 Adding The Implant Library In exocad
To use PIM data in exocad, the implant library selected during PIM project creation must be added in advance.
1. How to check the PIM project library
In DOFSync, check the name and details of the implant library that was set during the creation of the PIM project.
2. How to add the implant library in exocad
Add the implant library folder confirmed earlier to the implant library path in exocad.
- exocad library path : exocad > DentalCADApp > library > implant
️⚠️How To Download Implant Library⚠️
|
📘 Related Articles
📌 Using PIM Data In exocad
1. Exporting PIM Data To exocad From DOFSync
When DOFSync is linked with exocad, PIM data can be imported into exocad more easily and efficiently.
▶️ Related Video
- Linking DOFSync with exocad:
Follow the steps below to set up the integration between DOFSync and exocad.
- Exporting PIM data from DOFSync to exocad:
After completing the integration settings, PIM scan data can be exported directly from DOFSync to exocad.
All scan data and MUA position information are automatically applied in exocad during export.
2. Importing PIM Data In exocad
Copy the dentalProject file path of the PIM project, then open exocad DB or CAD to automatically load the PIM data and proceed with the CAD task.
- Checking the dentalProject file path:
Use the steps below to locate and copy the path of the dentalProject file to be imported into exocad.
- Importing PIM data in exocad DB:
Open the dentalProject file located in the copied folder through exocad DB to load the PIM data.
▶️ Related Video
- Importing PIM data in exocad CAD:
Open the dentalProject file located in the copied folder through exocad CAD to load the PIM data.
▶️ Related Video
📌 Set PIM Project Indication
To design an AOX prosthesis using PIM data, the project indication must be configured correctly before starting the design process in exocad.
1. Setting the AOX Prosthetic Type
To create an AOX prosthesis, the implant positions and adjacent tooth types must be configured correctly.
Refer to the guidelines below and set the appropriate prosthetic type for the adjacent teeth according to the prosthetic type assigned to the implant positions before proceeding with the design.
Implant Position Tooth Type |
Adjacent Tooth Type |
Required Selection |
|
Anatomic crown |
Anatomic pontic |
Antagonist
Adjacent Tooth Connector |
|
Anatomic waxup |
Pontic waxup |
|
|
Bar pillar |
Bar segment |
Refer to the document below for instructions on changing the indication settings of a PIM project in DOFSync.
📘 Related Articles
- How To Change PIM Project